Well, as I previously mentioned, the footprints are quite small, so we have 72 cm and 68 cm footprints: everything you need is conveniently located on the right side of the centrifuge, for example, the switch to turn on the centrifuge, a USB port to export data, a USB port for maintenance technicians, and a LAN connection, which allows you to connect the centrifuge to the network and the visionaries laboratory kit, which is very good; I will explain this further down in the article. Let's take a look at the overarching idea that I brought up earlier, shall we? This particular instance features what is known as a general barrel, which is attached to a general rotor. This means that when you switch between different types of barrels, you don't have to switch back and forth between barrel consumables, which is very good, but this is not the only part of the general concept, so it is composed of these general barrels and our general adapter, so let me put it back. It can be seen from the shape of the barrel that it can hold plates, pipes, as well as bottles in one barrel. Sorry about that, but we actually stock three different types of universal adapters. This is a yellow universal adapter that can fit our 15 ml tapered pipe, but you can also remove the upper part like this, and then you can use a spring label, a spring cover, or a screw cap to rotate our 5 ml pipe. If you remove the upper part like this, you can also rotate our 15 ml pipe.
This multi-purpose adapter, also known as our gray adapter, is what I refer to as the LEGO adapter. It has the capacity to hold a bottle with a flat bottom of 250 ml. This is a tiny socket, and something like this can be inserted into it. It is possible to remove it and make use of the third component of the adapter, which is this socket.
This is the refrigerated benchtop centrifuge that we enjoy using the most. You have the option of moving on to the program function. It has rotor identification and the current time, and you can even give the centrifuge a name. This allows it to tell you which router has been inserted. My centrifuge number 59, 10ri is labeled here for clarity, but you are free to call your device whatever you like. If you want to make any adjustments to these settings, you can do so with a simple touch. It only requires one click for you to be able to make the necessary adjustments.
Because of this, it is much simpler to create a new favorite, as it is possible that you will not require any speed settings at all. This couldn't be any easier to understand. You simply need to navigate to the speed section, for instance, and then set a new speed before you can use the refrigerated centrifuge to add something to your favorites. Simply select that, and then choose one of the existing favorites that you want to replace it with. That's all there is to it!
These days, creativity is in short supply. You will be given the following information: your program has been saved, and you have access to the demo program. You are able to switch between these two points at any time. For instance, you are able to start the program regardless of what you intend to do with it. First, we launch the demo program, and then we launch the actual program. Now, I'll launch a run in order to demonstrate the big running screen. The big running screen represents information. Unfortunately, the information regarding the remaining operating time is presented in very large letters in this location. Even the laboratory itself can be traversed.
We are going to have some webinars about digitalization at any time, and during those webinars, we will tell you more about this amazing product. Therefore, this is the refrigerated benchtop centrifuge of the program and the running screen. More centrifuges need to be made available. Therefore, let's return to the primary screen. Favorites. So, this place has a refrigerated centrifuge for managing documents, and it also manages users.
You can see the results of this reasoning right here: if you do not log in, you will not be able to use the favorites function. For instance, this refrigerated benchtop centrifuge has a very narrow range of application. It is possible that I will be able to use this refrigerated centrifuge once more after I have successfully logged in as an administrator or an ordinary user. Users with restricted access can only use the pre-programming software to start the operation or the pre-cooling software to start the operation. For instance, this is done to provide assistance to laboratories that are required to work in particular areas.
For instance, today was the first day of program one, and today was also the first day of program two. If you click on this run record, for instance, you will be able to view additional information, such as the run parameters. If there is any event, what is the serial number of the device, what is the rotor I use, and so on, in addition to all of these running records, it can, uh, it can save a lot of running records, uh, so you don't have to export these as every day, uh, but because of the number of running records you can choose, you can save them. This is because of the number of running records you can choose. You are able to filter. For instance, you only want to filter your run, or you only want to filter anything that has occurred either today or yesterday.
After that, with the help of this filtering function, you can select anything you want to export by clicking the export button, refrigerated centrifuge and then all you have to do is put the USB drive into the slot that's designated for it. You should be able to see that it has recognized the USB drive now, as I demonstrated to you just a few moments ago. It is now writing to the USB drive, which I can confirm is happening. You are able to export these data, and the resulting files will be in CSV or PDF format. Now, this document can be saved as a PDF. Once I receive confirmation, then everything will be stored on my memory stick.
You can put your mind at ease regarding the samples by removing the centrifuge from the wall or pulling it away from it. It's all good, thanks. This is something that piques my interest. An additional issue is that centrifuges have functions for user management and document storage. Does this mean that it adheres to GLP or GXP standards?
Users are free to work in any manner they see fit, including the development of new programs and the modification of existing ones. Because of this, if you write the program as a user and then I write the program as a user, we will both be able to edit the program together. The only role available in this centrifuge is that of a restricted user, who has no authority and cannot perform any actions. They, er, restricted users can only start programs in the same manner as these programs, which are already present; however, they are unable to set any new parameters, delete programs, or edit programs. Because of this, it is for the best if you only choose one administrator role and make the rest of the users restricted users. But if we are all just regular users, then you can't stop me from making changes to it even if you try.
On December 2, we received responses to all of our inquiries. During the course of the digital webinar series, we gave a presentation that was centered around the topic of "from ownership to users: your digital journey to the future laboratory."We are looking forward to meeting you there at the time of 9 a. m. Central European Time (CET). I hope you have a wonderful day and that you stay safe.